Hurikan 300

Hurikan 300

Animal & Fish
Metric
Burn Rate (Up to kg/h) Fuel Consumption Diesel (LPH)
300 17 - 23
Static Operational Dimensions (LxWxH) (m) Fuel Consumption LPG (LPH)
4.6 x 2.8 x 4.8 24 - 35
Chamber Load Capacity (kg) Fuel Consumption Nat Gas (m3/h)
1180 17 - 23
Imperial
Burn Rate (Up to Ibs/hr) Fuel Consumption Diesel (GPH)
662 4.4 – 6.2
Static Operational Dimensions (LxWxH) (ft/inch) Fuel Consumption LPG (GPH)
15’1’’ x 9’2’’ x 15’10’’ 5.5 – 9.2
Chamber Load Capacity (Ibs) Fuel Consumption Nat Gas (ft³/h)
2602 584 - 826
*Specification may be subject to change, as part of our continuous improvement plans.
Medical
Metric
Burn Rate (Up to kg/h) Fuel Consumption Diesel (LPH)
150 17 - 23
Static Operational Dimensions (LxWxH) (m) Fuel Consumption LPG (LPH)
4.6 x 2.8 x 4.8 24 - 35
Chamber Load Capacity (kg) Fuel Consumption Nat Gas (m3/h)
600 17 - 23
Imperial
Burn Rate (Up to Ibs/hr) Fuel Consumption Diesel (GPH)
331 4.4 – 6.2
Static Operational Dimensions (LxWxH) (ft/inch) Fuel Consumption LPG (GPH)
15’1’’ x 9’2’’ x 15’10’’ 5.5 – 9.2
Chamber Load Capacity (Ibs) Fuel Consumption Nat Gas (ft³/h)
1323 584 - 826
*Specification may be subject to change, as part of our continuous improvement plans.
Additional filtration may be required depending on local regulation.
General
Metric
Burn Rate (Up to kg/h) Fuel Consumption Diesel (LPH)
300 17 - 23
Static Operational Dimensions (LxWxH) (m) Fuel Consumption LPG (LPH)
4.6 x 2.8 x 4.8 24 - 35
Chamber Load Capacity (kg) Fuel Consumption Nat Gas (m3/h)
600 17 - 23
Imperial
Burn Rate (Up to Ibs/hr) Fuel Consumption Diesel (GPH)
662 4.4 – 6.2
Static Operational Dimensions (LxWxH) (ft/inch) Fuel Consumption LPG (GPH)
15’1’’ x 9’2’’ x 15’10’’ 5.5 – 9.2
Chamber Load Capacity (Ibs) Fuel Consumption Nat Gas (ft³/h)
1323 584 - 826
*Specification may be subject to change, as part of our continuous improvement plans.
Additional filtration may be required depending on local regulation.
High Capacity
Metric
Burn Rate (Up to kg/h) Fuel Consumption Diesel (LPH)
300 17 - 23
Static Operational Dimensions (LxWxH) (m) Fuel Consumption LPG (LPH)
4.6 x 2.8 x 4.8 24 - 35
Chamber Load Capacity (kg) Fuel Consumption Nat Gas (m3/h)
1180 17 - 23
Imperial
Burn Rate (Up to Ibs/hr) Fuel Consumption Diesel (GPH)
662 4.4 – 6.2
Static Operational Dimensions (LxWxH) (ft/inch) Fuel Consumption LPG (GPH)
15’1’’ x 9’2’’ x 15’10’’ 5.5 – 9.2
Chamber Load Capacity (Ibs) Fuel Consumption Nat Gas (ft³/h)
2602 584 - 826
*Specification may be subject to change, as part of our continuous improvement plans.

A top loading incinerator with a burn rate of up to 300kg per hour, this machine is ideal for the disposal of animal carcasses and abattoir waste. The Hurikan 300 is the perfect solution for on farm use where rapid and bio-secure waste disposal is required.

* Higher burn rate requirements may be achieved through our custom-built service.

Product Details

Ideally suited for:

  • A wide range of animal carcasses
  • Abattoir waste

Machine Construction

Integral to each model in the Hurikan Range is the unique Waste Spectrum monolithic casting system:

  • Ensures maximum strength and reliability in comparison to bricked linings
  • Materials expand and contract at the same rate as opposed to bricks and mortar
  • Prevents animal fats penetrating the lining which prolongs the life of the incinerator
  • Insulating board is used to reduce heat loss
  • Maintains an even working temperature for the refractory
  • Our Stainless Anchor System maintains the integrity of the lining

Features

  • Easy operation, full training provided
  • Mechanical or manual loading possible
  • Top loading design with easily moveable slide Open/Close lid. Its simplicity offers effortless operation
  • Market leading unique hearth bar technology allows for fast and complete incineration
  • Pulse fired burners, above and below hearth maximises throughput with 3 burners in the main chamber; 1 above hearth & 2 below hearth
  • High Capacity up to 300kg / hr burn rate enables fast disposal of waste
  • Ash doors, as standard, allows fast and efficient ash removal whilst in operation removing downtime
  • Temperature controlled pulse fired burners for optimal efficiency
  • Low thermal mass linings for minimal heat loss
  • PLC timer controls with automatic burner shut off function and rapid ignition pulse fired burners for low running costs
  • Can be loaded whilst in operation maximising the inherent thermal efficiency of our monolithic lining
  • A stainless steel, single skin exhaust stack is supplied as standard
  • Available as a static or **mobile system
  • Electrical Supply – Static unit works on a single phase 16 Amp 230 volt supply, fitted with a 3 pin round Euro plug. **Mobile unit powered by generator

Standard optional Extras

  • Ash rake
  • Additional chimney sections
  • USB Data Logger

* Mobile Optional Extras

  • Fuel tank
  • Generator
  • Safety platform ladder

Fuel Options

Diesel*, Kerosene*, LPG, Natural Gas and Bio Gas (* mobile only)

Regulatory

Due to its high capacity status the Hurikan 300 may require planning permission depending on your local authority regulations.

Our commitment

With more than two decades of design, engineering and manufacturing at Waste Spectrum our technical and sales teams have a reputation for working hard to support each and every customer. From choosing the right model through to assisting with technical advice and ongoing day to day engineering support, we are proud to share our expertise.

Our knowledge and experience of a wide range of industries enables us to work closely at every stage of the planning and installation process.

For more information please call 01905 362100 to speak with one of our specialist teams.

Warranty

All Waste Spectrum incinerators come with a * 2 year warranty as standard.
* 2 years or 2080 hours

Hurikan 300